Rotameter theory pdf file

The variety in cones, floats and scales combine to make the yokogawa rotameter suitable for a very wide range of applications. This mechanical principle is as simple as it is reliable. With the flow regulating valve of the bench closed, switch on the bench pump and allow water to be pumped into the apparatus by controlling the opening of the flow regulating valve until water just begins to flow into the equipment and just overflows through the air vent above the rotameter. Rotameter floats design on the performance of a rotameter. Rotameters work on the principle of vameters and are used. Theories of learning and teaching what do they mean for. A device used to measure fluid flow, in which a float rises in a tapered vertical tube to a height dependent on the rate of flow through the tube. It measures flow rate by allowing the crosssectional area the fluid travels through, to vary, causing a measurable effect. Their top six responses are clues as to why a rotameter continues to be successful even after a hundred years. To change the order of your pdfs, drag and drop the files as you want. A rotameter is a device that measures the flow rate of liquid or gas in a closed tube rotameter.

Working principle of rotameters the rotameter s operation is based on the variable area principle. The float rises within the tube as the flow increases. Rotameter flow meters are devices that can measure the flowrate of liquids and gases. A rotameter is a device that measures the volumetric flow rate of fluid in a closed tube it belongs to a class of meters called variable area meters, which measure flow rate by allowing the crosssectional area the fluid travels through to vary, causing a measurable effect.

Saumil b patel 4 used the cfd software for the analysis of an. The function of the float blockage detection system allows the electrical transmitter to distinguish the fluctuations, which are caused by a moving float, with the. Aug 31, 2017 fully explained rotameter and also called variable flow meter. A rotameter consists of a tapered tube, typically made of glass with a float, made either of anodized aluminum or a ceramic, actually a shaped weight, inside that is pushed up by the drag force of the flow and pulled down by gravity. The variable area flowmeter is one of the oldest and mature principles in flow measurement with its simple design. In the 1990s, yokogawa strengthened its focus on flowmeters through the acquisition of the german flowmeter manufacturer rota. The rotameter is popular because it has a linear scale, a relatively long measurement range, and low pressure drop. Overview of flowmeter models matheson offers a complete line of variable area flowmeters. In the case of omega laboratory rotameters, far greater flexability is possible through the use of correlation equations. Yaqob 3 calculating correction factor c f, which is the ratio between the rotameter reading q rot. The variable area meter rotameter a rotameter consists of a gradually tapered glass tube mounted vertically in a frame with the large end up. Then cfd analysis is used for analyzing drag force using cfd modeling software, gambit is used for designing the fluid inside the rotameter. The motivation for this experiment was to determine whether the use of a rotameter would be feasible in the chemical dose controlling system.

Sep 11, 2014 rotameter variable area meter what is rotameter. Please, select more pdf files by clicking again on select pdf files. To find the coefficient of discharge for orifice meter. The variable area flowmeter is an instrument for measuring the flow of liquids and gases in pipelines. But the major advantages of rotameter are, it is simple in construction, ready to install and the flow rate can be directly seen on a calibrated scale, without the help of any other device, e. Effect of float design on the performance of rotameter. The rotameter gets its name from the rotating float which was developed by rota to provide self stabilization. Theory and calibration procedures for the use of a rotameter. Failsafe inline flow indication under any circumstance.

Its accuracy is also less compared to other types of flow meters. Benchmarks for learning and teaching benchmarks for learning knowledge teaching moving from passive absorption of information. Ensure that there are no air bubbles trapped in the manometer tubes, if. Rotameter working principle animation instrumentationtools. Generally, the rotameter is a tube made of plastic, glass or metal combined with a float, which responds linearly to the flowrate of the fluid in that tube. Theory and calibration procedures for the use of a rotameter f. Oriflowrator meters series 10b4500 providing lowcost measurement of large liquid or gas. If a wide range of flows is expected, a dualball rotameter can be used. Basic construction, armored metal tube flowmeter the flowrates listed flow range tables are based on floats made of 304 1.

The float response to flowrate changes is linear, and a 10to1 flow range or turndown is standard. Thank you, for helping us keep this platform clean. Reliable, easytoread displays on all flow meter types. It is a variablearea meter with a float moving freely in a tapered tube. The invention and working principle of rotameter flow. Today we have one of the highest global install rates, as well as one of the largest customer bases and broadest ranges of rotameters. To study direct comparison of flow measurement by using an orifice plate, venturi meter and variable area meter rotameter. From the experiments it is concluded that position of float remains same for the small change in flow rate of water and performance of rotameter directly depends on the float design and drag force offered on the float.

Rotameters can be configured to either measure liquid or gas flow. For the love of physics walter lewin may 16, 2011 duration. Figure objectives the objectives of the experiment are. The amplitude characteristics of rotameters v and vi.

The reasons that affects the accuracy of the rotameter meter variety, rotor type flowmeters, electromagnetic flowmeter, turbine vortex flowmeters, mass flow meter, etc. The rotameter should be used only for the fluid or gas for which it is designed. Under a constant flow rate, the position of the float stabilizes. The rotameter consists of a plastic, metal or glass tube and float. The rotameter figure f1 is a variable area meter which consists of a vertical, tapered, transparent tube containing a float. The calibration of standard tubes is carried out by comparing.

A rotameter flow meter is used to measure the flowrate of liquids and gases. Mar, 2016 rotameter is considered as an orifice meter with the variable aperture, thus the formula used for orifice with slight changes can be used. Fm 308 flow measurement by venturi and orifice meter. The rotameter offers the advantage of a wide range of flow rates that can be directly measured. Neuroscientists, for example, learned that the brain actively seeks new stimuli in the environment from which to 2 theories of learning and teaching table 1. In some operations, the ability to conduct accurate flow measurements is so important that it can make the difference between making a profit and taking a loss. The float moves upward as the fluid flow increases. The float in the rotameter is located at one place to avoid damage during transit.

Theory as a rotameter bobbin moves up the tapered tube, the crosssectional area of fluid surrounding the bobbin increases, and providing there is a sufficiently great difference in conductivity between the bobbin material andthe fluid, it follows thatthe resistanceoffered to current. You can watch all lectures of tom and fluid mechanics. Each cad and any associated text, image or data is in no way sponsored by or affiliated with any company, organization or realworld item, product, or good it may purport to portray. We have the ability to design and manufacture customer specific solutions. We built this reputation on customer oriented solutions.

The effects of fluid viscosity on the orifice rotameter. Merge pdf files combine pdfs in the order you want with the easiest pdf merger available. Valves placed at the outlet of the meter can allow for this to occur. Overview rotameter type ramc metal short stroke rotameter rakd mini rotameter ragg housing rotameter measurable flow rates water 20c min. In the 1990s, yokogawa strengthened its focus on flow meters through cooperation with and the eventual acquisition of the german flow meter manufacturer rota.

This broad portfolio includes armored metal, glass tube and plastic va flow meters rotameters, each engineered to provide years of repeatable, reliable measurement of gas and liquid flow rates. And an other engineering subjects waat governor principle and working s. Rotameter variable area flowmeter yokogawa electric. Flow capacities ranges for the flowmeters described in this catalog are given for air at standard conditions t 14. A rotameter is one particular type of variable area flowmeter that measures flow by varying the crosssectional area a fluid or gas travels through in a closed tube.

The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross sectional area of the float. The bob has a diameter of 15 mm and a volume of 3 ml. The basic function of rotameter flow meters is based on the variable area theory. Going with the name, rotatmeter was called rotameter because they usually function by rotating in the glass tube. In the case of metal rotameters of type ramc, the special shape of the float results in less dependence on viscosity at lower viscosities. For each flowrate, the float is lifted to some point at. Variable area flowmeter rotameter the original insatech. As a result, yokogawa gained access to 100 years of flow meter expertise and completed its flow meter portfolio by adding the rotameter variable area and rotamass coriolis product lines. Rotameter head loss experiment aguaclara dashboard. Swagelok variable area flowmeters must be installed, operated, and serviced according to nec, applicable local regulations, and these instructions. Principles of rotameter flowmeter when fluid or gas flows through a taper tube containing a float, a pressure difference of p1 and p2 is created between upper and lower side of the float. Rotameters are flowmeters that measure fluid flow rate using force.

Rotameters are typically provided with calibration data and direct reading scales for commonlyused fluids air and water. The rotameters operation is based on the variable area principle. As per variable flow theory, the flow raises the float in the tapered tube that increases the passage area of the liquid flow. A rotameter is to be designed to measure a maximum flow rate of 200 lpm of water at 27 degree c.

Position the water flow measuring apparatus on the horizontal operating surface of the hydraulics bench 2. To find the coefficient of discharge for venturi meter. The flowmeter rotameter on the far left side measures from 0. Rotameters variable area flow meters yokogawa america. The developed theory has been verified experimentally using typical rotameter equipped with the plumb type float, for water of 15 c and having a flow rate range from 10 to 100 lhr. Introduction to pipe flow measurement the process piping. Pdf the flow in a floating element flow meter rotameter was studied with. Sizing a rotameter for use with other fluids requires conversion into one of those standard formats. Measuring the flow of liquids and gases is a critical need in many industrial plants.

Open or close the red globe valves so the circuit for the flowmeter rotameter to be calibrated is open. The effective density of the bob is twice the density of water. Rgc1 series glass rotameter rgc2 series glass rotameter rqc1 series. Jul 24, 2016 for the love of physics walter lewin may 16, 2011 duration. Otherwise, serious personal injuries, damage, or both can occur. Our network of distributors provide the user with fast delivery, widespread parts availability and solid service support. Rotameter variablearea flow meters can be calibrated to measure nearly any gas or liquid, because their principles of operation are simple and well understood. This is done using a uniformly tapered tube, a float whose diameter is nearly. Pdf investigation of flow in a rotameter researchgate. In the case of omega laboratory rotameters, far greater flexability is possible through the use of. The flow indication is obtained from a balance of the fluid forces underneath the float with gravity. Variable area basic fundamentals flowmeter and descriptions.

Working principle of rotameters the rotameters operation is based on the variable area principle. Theory as a rotameter bobbin moves up the tapered tube, the crosssectional area of fluid surrounding the bobbin increases, and providing there is a sufficiently great difference in conductivity between the bobbin material andthe fluid, it. Pdf the float motion mathematical model is established based on the theory of flow around a body in this paper, by solving the mathematic. The editors will have a look at it as soon as possible. Customers have been asked why they select rotameters. It belongs to a class of meters called variable area meters, which measure flow rate by allowing the crosssectional area the fluid travels through, to vary, causing a measurable effect.

Rotameter applications extend across industries because it was and still is an economical way of measuring very low to high flow rates. It belongs to a class of meters called variable area meters, which measure flow rate by allowing the crosssectional area the fluid travels through to vary, causing a measurable effect. Variable area flowmeter ariable area flowmeter rotameter. A rotameter is a device that measures the volumetric flow rate of fluid in a closed tube. A variable ring or annulus is created between the outer diameter of the float and the inner wall of the tube. A two dimension model of rotameter is designed using gambit and boundary conditions were applied to the geometry after meshing the geometry for this project. The rotameter variable area principle the rotameter is one of the oldest and mature principles in flow measurement. Calibration of an orifice plate flowmeter mechanical engineering department king saud university riyadh submitted by. A rotameter can be included between the constant head tank and the flow control orifice in the dose controller to verify the flow rate of chemical. The fluid flow rate is directly related to the location of the float, with larger flow rates. Effect of float design on the performance of rotameter using. Fm 308 flow measurement by venturi and orifice meter objectives. Omega laboratory rotameters are far more versatile due to the use they make of correlation equations. The electrical connections provided on any electronic relays should be used as originally supplied and not bypassed or modifed other.

The computeraided design cad files and all associated content posted to this website are created, uploaded, managed and owned by third party users. The total length of the rotameter tube is 150 mm and the diameter of the tube at its inlet is 15 mm. An introduction to flow measurement with rotameters. From boundary layer theory, the pressure of the plug flow at is transmitted across the assumed stagnate interval from the plug to the pressure port. Pdf the float motion analysis in rotameter researchgate.

The reasons that affects the accuracy of the rotameter. Rotametersvariable area flow meters tech info from coleparmer. The black ball is read until it goes off scale, and. Theory this flow meter measurement apparatus has been designed to introduce students to the operating characteristics of various types of. The float motion analysis in rotameter article pdf available in applied mechanics and materials 2122. The rotameter is known all over the world as a reliable measurement instrument and nowadays as a synonym for variable area meters. Stainless steel tube rotameter for high temperatures fluids magnetic float for turbid fluids 14. Energy losses through venturi, orifice, and rotameter flowmeters. How to install a rotameter a rotameter, also known as a variable area flowmeter, is a device that measures the flow rate of liquid or gas in a closed tube. In so doing yokogawa gained access to 100 years of flowmeter expertise and completed its flowmeter portfolio by adding the rotameter variable area and rotamass coriolis product lines. Their top six responses are clues as to why a rotameter continues to.

It is a variable area meter which works on the principle of upthurst force exerted by fluid and force of gravity. Switch the pump on, allow the water to enter the flow measurement instruments,which are connected to manometers tubes. Venturi meter and orifice meter are the commonly used flow meters for measuring massvolumetric flow rate or velocity of the flowing fluid. Sep 26, 2017 rotameter can be only be used in a vertical pipeline. The effects of fluid viscosity on the orifice rotameter in. Variable area flowmeter basic fundamentals and descriptions. The fluidws temperature, pressure and specific gravity all impact gas flow measurements.

198 481 918 1244 1191 1384 1294 1261 149 1099 1308 591 924 659 1300 930 1126 270 315 157 1214 170 318 584 251 1410 183 901